Biological Safety Cabinets
Mycron Air Tech presents its Bio Safety Cabinets are made of GI powder coated and stainless steel 304 grades with international quality standard components. A biological safety cabinet also called as Bio Safety Cabinet (BSC). It is an enclosed, ventilated laboratory workspace for safely working with materials contaminated with (or potentially contaminated with) pathogens requiring a defined bio-safety level. Several different types of BSC exist.
Get In Touch
Mycron Provides the best laboratory experience
mycronis the best diagnostic lab in the city. I have great experience with them. The provide authentic results & have the best environment inside here. I highly recommend them. mycron is the best diagnostic lab in the city. I have great experience with them. The provide authentic results.
Class I cabinets provide personnel and environmental protection. These BSCs are commonly used to enclose specific equipment or procedures that potentially generate aerosols. BSCs of this class are either ducted (connected to the building exhaust system) or without ducted (recirculation filtered exhaust back into the laboratory).
Class II cabinets provide both kinds of protection of the samples and of the environment since makeup air is also HEPA-filtered. There are four types: Type A1, A2 and Type B1, B2.
The Class III cabinet, generally only installed in maximum containment laboratories. It is specifically designed for work with BSL-4 pathogenic agents, providing maximum protection. The enclosure is gas-tight, and all materials enter and leave through a dunk tank or double-door Passbox. Gloves attached to the front prevent direct contact with hazardous materials. These cabinets are sometimes called glove box.
Bio Safety Cabinet Class II Type A2
| Sl.No | Features | Specifications |
|---|---|---|
| 1 | Available Sizes for Working Area in feet’s (LxBxH) | 2x2x2 , 3x2x2, 4x2x2, 6x2x2 |
| 2 | Material of Construction | GI Power coated, SS 304/316 |
| 3 | MOC of Working Area | SS 304/316 |
| Cleanliness Level | ISO class 5 as per ISO 14644-1 | |
| Air Balancing | 70% recirculation / 30% exhaust | |
| 4 | HEPA Filter (Supply and Exhaust) | HEPA Filter having EU 14 rating with suitable size. Efficiency – 99.997% down to 0.3 Microns. |
| 5 | Pre Filter | EU 4 rating with suitable size. Efficiency – 90% down to 10 Microns |
| 6 | Motor & Blower | Dynamically balanced Motor with Aluminum Impeller |
| 7 | Door | 5mm Polycarbonate Sliding Door |
| 8 | Gas Supply Provision | Yes |
| 9 | Illumination | Minimum 900 lux inside the working area |
| 10 | UV Lamp | Yes |
| 11 | UV Hour Meter | Yes |
| 12 | Power Socket | Yes, 20A |
| 13 | Pressure Gauge | 01 No with each unit (To measure differential pressure across the supply HEPA filter) |
| 14 | Duct | Yes, Up to 10 feet with one Elbow |
| 15 | Power Required | 230V/50 Hz |
| 16 | Total Power Consumption | 2 KW |
| 17 | Noise Level | Less than 70 DB |
| 18 | Vibration Level | < 2.5 µm (0.000025 m) |
Bio Safety Cabinet Class II Type B2
| Sl.No | Features | Specifications |
|---|---|---|
| 1 | Available Sizes for Working Area in feet’s (LxBxH) | 2x2x2 , 3x2x2, 4x2x2, 6x2x2 |
| 2 | Material of Construction | GI Power coated, SS 304/316 |
| 3 | MOC of Working Area | SS 304/316 |
| 4 | Cleanliness Level | ISO class 5 as per ISO 14644-1 |
| 5 | Air Balancing | 0% recirculation / 100% exhaust |
| 6 | HEPA Filter (Supply and Exhaust) | HEPA Filter having EU 14 rating with suitable size. Efficiency – 99.997% down to 0.3 Microns. |
| 7 | Pre Filter | EU 4 rating with suitable size. Efficiency – 90% down to 10 Microns |
| 8 | Motor & Blower | Dynamically balanced Motor with Aluminum Impeller |
| 9 | Door | 5mm Polycarbonate Sliding Door |
| 10 | Gas Supply Provision | Yes |
| 11 | Illumination | Minimum 900 lux inside the working area |
| 12 | UV Lamp | Yes |
| 13 | UV Hour Meter | Yes |
| 14 | Power Socket | Yes, 5A |
| 15 | Pressure Gauge | 01 No with each unit (To measure differential pressure across the supply HEPA filter) |
| 16 | Duct | Yes, Up to 10 feet with one Elbow |
| 17 | Power Required | 230V/50 Hz |
| 18 | Total Power Consumption | 2 KW |
| 19 | Noise Level | Less than 70 DB |
| 20 | Vibration Level | < 2.5 µm (0.000025 m) |
Bio Safety Cabinet Class III
| Sl.No | Features | Specifications |
|---|---|---|
| 1 | Available Sizes for Working Area in feet’s (LxBxH) | 2x2x2 , 3x2x2, 4x2x2, 6x2x2 |
| 2 | Material of Construction | GI Power coated, SS 304/316 |
| 3 | MOC of Working Area | SS 304/316 |
| 4 | Cleanliness Level | ISO class 5 as per ISO 14644-1 |
| 5 | Air Balancing | 0% recirculation / 100% exhaust |
| 6 | HEPA Filter (Exhaust and Inlet) | HEPA Filter having EU 14 rating with suitable size. Efficiency – 99.997% down to 0.3 Microns. |
| 7 | Pre Filter | EU 4 rating with suitable size. Efficiency – 90% down to 10 Microns |
| 8 | Motor & Blower | Dynamically balanced Motor with Aluminum Impeller |
| 9 | Door | 8mm Polycarbonate with Glove Port |
| 10 | Gas Supply Provision | Yes |
| 11 | Illumination | Minimum 900 lux inside the working area |
| 12 | UV Lamp | Yes |
| 13 | UV Hour Meter | Yes |
| 14 | Power Socket | Yes, 20A |
| 15 | Pressure Gauge | 01 No with each unit (To measure differential pressure across the supply HEPA filter) |
| 16 | Duct | Yes, Up to 10 feet with one Elbow |
| 17 | Power Required | Single Phase 230V/50 Hz |
| 18 | Total Power Consumption | 2 KW |
| 19 | Noise Level | Less than 70 DB |
| 20 | Vibration Level | < 2.5 µm (0.000025 m) |
Service FAQ
Do we need prescription for these testing?
Patholab’s Complete Care Geno identify DNA variant specific to an individual & provides report about detoxification. Hormone Insight can be useful at the Various stages of life.
What is the cost for these testing?
Patholab’s Complete Care Geno identify DNA variant specific to an individual & provides report about detoxification. Hormone Insight can be useful at the Various stages of life.
Do I have to come with empty stomach?
Patholab’s Complete Care Geno identify DNA variant specific to an individual & provides report about detoxification. Hormone Insight can be useful at the Various stages of life.
How much time it takes for report delivery?
Patholab’s Complete Care Geno identify DNA variant specific to an individual & provides report about detoxification. Hormone Insight can be useful at the Various stages of life.
What are the payment methods here?
Patholab’s Complete Care Geno identify DNA variant specific to an individual & provides report about detoxification. Hormone Insight can be useful at the Various stages of life.
Should I bring previous reports of mine?
Patholab’s Complete Care Geno identify DNA variant specific to an individual & provides report about detoxification. Hormone Insight can be useful at the Various stages of life.
How many tests are available for lipid profile?
Patholab’s Complete Care Geno identify DNA variant specific to an individual & provides report about detoxification. Hormone Insight can be useful at the Various stages of life.
MycronProvides the best laboratory experience
15 Years of Experience
Translucent business dealings
On time delivery
Features & Specifications
Clients Testimonial
Ravi K
Ananya S